• Xenox C100

  • mobile c-arm
  • Xenox C100 is a reliable, tough and enduring mobile c-arm , with the maximum affordability; intuitive software for different configurations with user-friendly interface

 

  • Xenox C100 avaialble in diffrent models: with rotating anode tube or stationary one & Image Intensifier 9” or 12” (only for rotating version) 
  • Horizontal run 210 mm
  • Arc orbital Movement 135°
  • WIG-WAG ±12,5°
  • C-arm depth 690 mm
  • S. I. D. 988 mm/980 mm/920 mm
  • Arm rotation around horizontal axis ±270°
  • Generator power in DC current 5 kW (3,5kW@115 Vac)
  • Generator operating frequency 40 kHz
  • KV range 40 -h 120 kV
  • Max current in continuous fluoroscopy 8,0 mA
  • Max current in «SNAPSHOT» fluoroscopy 30 mA
  • Max current in HCF with DFG (HRP)30 mA
  • Max current in pulsed fluorography with DFG (HRP)60 mA@230 Vac;45 mA@115 Vac
  • Max current in digital graphy-mode with DFG (HRP)60 mA@230 Vac;45 mA@115 Vac
  • Max current in radiography (hi-rad) 35 mA @ 115 Vac ; 50 mA @ 230 Vac
  • Max mas in radiography 90 mAs @ 115 Vac -;125 mAs @ 230 Vac
  • MAX FLUOROSCOPY TIME H.U. Safety after 28 min of fluoroscopy @120 kV, 5 mA (600W)
  • Membrane keyboard with alphanumeric touch-screen 5.7” LCD display for all the operative parameters and error messages. Microprocessor management. Keyboard can be rotated of ± 60° 

Operating Modes and Functionality

OPERATING MODALITIES OF MEMORY

CONTINUOS FLUOROSCOPY
PULSED FLUOROSCOPY (12/sec, 6/sec, 3/sec, 1/sec - without acquisition on hard disk)
DIGITAL SNAPSHOT
FLUOROSCOPY mA (1/2): (range: 0,25-4 mA)
RADIOGRAPHY: 2 points technique (kV & mAs)
 

Digital video processing

  • Number of images on Hard Disk: about 55.000 (Hard Disk 128 GB)
  • Video output: 1 x HDMI 1960x1200
  • Image format on the working memory: 1024 x 1024 x 12 bit
  • Number of monitors: 1 24“ LCD
  • Optional: Hard Disk of 256 GB (about 110.000 images)

Software:

Functions: selection of anatomic programs; recursive filter (1,2,4,8,16); edge enhancement Smooth, Normal, Sharp in post processing; smart filter with «motion detection^; grey scale inversion; brightness and contrast; virtual collimator, horizontal and vertical flip; electronic rotation at 1° step; Electronic zoom factor from 1,2 to 3; Electronic lens factor from 1,2 to 3; Overview (4,9,16 images); Text editing; Dose report; Patients archive; Interface for network Ethernet TCP/IP; Export single BMP image on USB

Measure tools (included in basic configuration): length, angles, stenosis, length calibration on reference object; text overlay

  • 12" and 9" image intensifier option available
  • High Frequency monoblock X-ray generator 5 KW
  • 1k CCD camera delivers sharp and detail-rich images
  • Keyboard can be rotated of ± 60° 
  • Modular configurations even after sales
  • HD storage memory
  • Full Dicom(optional)
  • Triple footswitch fluoroscopy control
  • 210 mm horizontal C-arm run, with manual brake for locking
  • Orbital movement 135°
  • 270° on each side arm rotation, with manual brake for locking.
  • 12° on each side C-arm swivelling with manual brake for locking. 
  • Monitor trolley with 24" LCD Monitor
  • Realtime and post processing features

  • Traumatology
  • Orthopedics
  • Digestive system             
  • Generic Surgery
  • Biliary drainage and stenting      
  • Image guided biopsy
  • Neonatology and pediatrics
  • Lithotripsy

  • DICOM package:
    Dicom VERIFY (SCU/SCP), Dicom STORAGE, Dicom WORKLIST (SCU), Dicom PRINT (SCU), Dicom CDR/D VD, Dicom QUERY/RETRIEVE (SCU), Dicom MPPS (CPU), Dicom STORAGE COMMITMENT (SCU), Dicom DOSE STRUCTURED REPORT
  • HARD DISK SSD 256 GB (about 110.000 images)
  • Thermal printer
  • Patient radiation dose measuring device (DAP chamber)
  • Laser localizer for centering the anatomical area to be examined on the I.I. side
  • 24x30 cm or 18x24 cm or 10x12’’ Cassette Holder (9” I.I.)
  • 35x35 cm Cassette Holder (12” 1.1.)

Related Links
Xenox C200Xenox M300CV