Marcom 0.35T

Open MRI system

PRODUCT ENQUIRY

Would you like to know more about the product or receive prices for a project?
Please fill in the form on the right, and we will gladly answer your questions.
You can also contact us by phone or e-mail.

 +49 751 35 97 8-0
 +49 151 55 79 49 96​
 email@sternmed.de

    300

    Marcom 0.35T 
    Open MRI system

    Marcom 0.35T is an open 0.35T permanent magnet MRI scanner which supplies fast imaging and high-quality images and provides rich preset scan protocols as well as advanced applications.

    Features

    Eddy zero technology

    The shimming algorithm technology (ensures field strength with high uniformity and stability), ensure the MRI system operating stable with high quality and high performance.

    Eddy Zero Technology:

    • Magnet design uses breakthrough anti-eddy current technology
    • The gradient coil using self-shielded active anti – eddy current technology
    • Implementation of precision eddy current compensation algorithm, completely eliminate the impact of eddy current.

    The eddy current because of the high gradient and high slew rate come from ultra-fast sequence was resolved completely, which guarantee to get the best clinic image.

    Open wide design

    More patient comfort and more space for surgery. Affinity C-shape magnets, creating a maximum of openness, offer a maximum vision for patients, especially leave much space comfort for obese patients, minimizing claustrophobia of patients and providing more space for MR intervention surgery.

    Advance gradient system

    The gradient system helps to provide higher resolution pictures. The Marcom 0.35T (X , Y, Z) gradient intensity is 25 mT/m, providing higher gradient intensity, faster imaging speed, shorter scanning time, thinner imaging slice and higher image resolution.

    The new technology of 4D shimming

    Use of advanced active shimming algorithm for real-time automatic shimming on each examination to ensure the magnetic field always maintain the highest uniformity. Magnetic field homogeneity and stability of the MRI images always are the most important guarantee of the high-resolution, high SNR and high contrast. They are the important indicators of the level of magnet design, the better the smaller the value. It directly determines the SNR of the image, like a car chassis, where stability is essential., The magnetic field uniformity is maintained at < 2.5 ppm in 40cm the DSV Vrms, allowing the system to complete a wide range of scanning (40 cm).

    Advanced RF system

    The Marcom 0.35T is equipped with fast 4 channels RF system and all phased array coils providing best SNR pictures.

    Product images

    Clinical Use / Images