• Xenox C300 & C400

  • mobile c-arm
  • The Xenox C400 is a highly reliable, tough and enduring digital mobile system with flat panel equipped with digital angiographic memory suitable for all the applications having high diagnostic content. The device is designed to provide the best performance with maximum affordability. This device is also available with image intensifier as the Xenox C300. Its ease of handling, x-ray parameters, image quality and safety are some of its main advantages.

Xenox C400

  • Horizontal run: Manual moving 210 mm; E-Motion 175 mm
  • Motorized Vertical run: 500 mm; 500 mm
  • C-Arm LATERAL Rotation: ± 140° ( ± 180° * ); + 180°; - 90° (-180° manual)
  • C-Arm ORBITAL Movement: 150° (105°,-45°); 150° (105°,-45°)
  • WIG-WAG: ± 10°; ± 10°
  • Useful Space: 810 mm; 810 mm
  • C-Arm Depth: 640 mm; 640 mm
  • Min/ Max Height: 1455 / 1955 mm; 1455 / 1955 mm
  • Min/Max Length: 2085/ 2295 mm; 2110/ 2285 mm
  • Max Width: 800 mm; 800 mm
  • S.I.D.: 1065 mm; 1065 mm
    *Measure obtained without security mechanical block

Xenox C300

  • Horizontal run: Manual moving 9" 210 mm; E-Motion 9" 175 mm; E-Motion 12" 210 mm
  • Motorized Vertical run: 500 mm; 500 mm; 460 mm
  • C-Arm LATERAL Rotation: ± 140° ( ± 180° * ); + 180° - 90° (-180° manual);+ 180° - 90° (-180° manual)
  • C-Arm ORBITAL Movement: 135° (90°+45°); 135° (90°+45°); 115° (90°+25°)
  • WIG-WAG: ± 10°; ± 10°; ± 10°
  • Useful Space: 755mm; 755mm; 708mm
  • C-Arm Depth: 665mm; 665mm; 640mm
  • Min/ Max Height: 1750 / 2250 mm;  1750 / 2250 mm; 1805/ 2265mm
  • Min/Max Length: 2075/ 2285 mm; 2100/ 2275 mm; 2118/ 2293 mm
  • Max Width: 800 mm; 800 mm; 800 mm
  • S.I.D.: 1029 mm; 1029 mm; 1009mm
    *Measure obtained without security mechanical block

Operating Modes and Functionality

OPERATING MODALITIES OF MEMORY

  • CONTINUOUS FLUOROSCOPY
  • HIGH DOSE PULSED FLUOROSCOPY
  • PULSED FLUOROGRAPHY
  • DIGITAL SNAPSHOT
  • FLUOROSCOPY mA: (range: 0,5-8 mA)
  • RADIOGRAPHY: 2 points technique (kV and mAs)
  • CINE sequence: up to 25 fps. (included in basic configuration)

(DFG) Digital video processing

  • Number of images on Hard Disk: 200.000 max resolution
    images acquired (1536x1536)
  • Number of images on Hard Disk: 400.000 max resolution
    images acquired (1024x1024)
  • Digital Memories: -1,5k x 1,5k, with acquisition up to
    25 fps (for Xenox C400); -1k x 1k, with acquisition up
    to 30 frames/sec (for Xenox C300)
  • Video output: 2 x DVI 1280x1024
  • Image format of the working memory: Xenox C400:
    with 21 x 21 FBD 1024 x 1024 x 16 bit and with 30 x
    30 FBD 1536 x 1536 x 16bit; Xenox C300:1024 x 1024
    x 12 bit
  • Image format: 1024 x 1024 x 16 bit
  • Number of monitors: 27” High Resolution main monitor
    and a dedicated 21,5” Touch Screen monitor

SOFTWARE BASE FUNTION (LIVE PROCESSING):

  • Display of patient data, hospital name, x-ray parameters
    on operator monitor
  • Recursive filter for noise reduction
  • Dinamic Recursive Filter for patient’s movement compensation
  • Edge enhancement spatial filter
  • Edge enhancement spatial filter
  • Horizontal and vertical image inversion
  • Digital zoom during fluoroscopy mode (new)
  • Metal detection in manual or automatic mode (new)
  • Continuous digital image rotation
  • Adjustable contrast and brightness
  • Adaptive gamma curve
  • Continuous fluoroscopy modality with LIH (Last Image
    Hold)
  • Low dose fluoroscopy
  • Timer Function
  • MEASUREMENTS: length, angles, with manual calibration
    system, text overlay
  • Anatomic program set up
  • 80 anatomic programs in fluoroscope

POST-PROCESSING BASE FEATURES:

  • Last Image Hold (LIH)
  • Last fluoroscopy Run Hold (LRH)
  • Horizontal/Vertical image inversion
  • Digital image rotation
  • Grey scale image inversion
  • Adjustable contrast and brightness
  • Adjustable Gamma curve (LUT)
  • Edge enhancement
  • Electronic shutters (Rectangular and circular)
  • Electronic Zoom Roam from 1x to 5x
  • Electronic mobile lens
  • Mosaic Overview
  • Patient’s selection for exams and images management
  • Patient’s exams transfer in the DICOM system

  • Xenox C400 (with Flat Panel) 30x30 or 21x21 cm
  • 12“ and 9“ image intensifier option available as
    Xenox C300
  • Digital Memories: 1,5k x 1,5k, with acquisition up
    to 25 fps (for Xenox C400); 1kx1k, with acquisition
    up to 30 frames/sec (for Xenox C300)
  • 30 kW H.V. Generator
  • DUAL COOLING System for immediate and effective
    heat removal
  • DUAL POWER System: power reserve system
  • E-Motion System: C-arm movements, fully
    motorized (optional)
  • 215 mm Horizontal Run (17 mm in motorized
    version)
  • Wide orbital movement 150°
  • C-arm Lateral rotation: ± 180°
  • 10“ Touch Screen control console

• Electrophysiology studies
• Angiographic procedures
• Vascular surgery
• Endovascular applications
• Urology procedures
• Catheter procedures
• Neuroradiology
• General surgery
• Traumatology
• Orthopaedic
• Interventional radiology

OPTIONS

  • DSA OPTION: Real time DSA with mask, Real time
    DSA with CO2 contrast liquid, Max opacity modality,
    Land marking, Road mapping, Mask selection for road
    mapping function, Virtual Road Mapping using fluorography
    image, Autoinjector delay selection, “CO2”
    contrast injection modality, Vascular tracing Function,
    Mask replace function, “Pixel shifting” function, Stenosi
    misure. In case the options are present all the relative
    functions are activated
  • DICOM FUNCTION (Option): DICOM VERIFY, DICOM
    STORAGE, DICOM WORKLIST, DICOM MEDIA INTERCHANGE, DICOM SEND, DICOM MPPS, DICOM STRUCTURED REPORT, DICOM QUERY/RETRIEVE (Q/R), DICOM
    PRINT INTERFACE WITH DICOM FILM EDITOR
  • Thermal printer
  • Patient radiation dose measuring device (DAP chamber)
  • Laser localizer for centering the anatomical area to be
    examined on the I.I. side
  • Remote wireless footswitch